Menu
My MVS
My MVS

ACI 309-72 PDF

Posted on September 12, 2019 by admin

ACI Standard. Recommended Practice for. Consolidation of Concrete (ACI 72). D. H. BASGEN. R. H. BRUBAKER. JOHN C. FARMER. LARS FORSSBLAD. Recommended Practice for Consolidation of Concrete (ACI ). Front Cover. American Concrete Institute. American Concrete Institute, – Concrete – Recommended Practice for Consolidation of Concrete (ACI ) (Reaffirmed ). Front Cover. ACI Committee American Concrete Institute,

Author: Goltijinn Taukus
Country: Estonia
Language: English (Spanish)
Genre: Software
Published (Last): 13 April 2015
Pages: 67
PDF File Size: 4.7 Mb
ePub File Size: 20.80 Mb
ISBN: 413-3-87936-746-8
Downloads: 95751
Price: Free* [*Free Regsitration Required]
Uploader: Daidal

All excess release agent shall be blown or wiped off before the form and liner is put back into service. Do not use damaged products. Requests for substitutions will be considered in afi with provisions of Section On multiple use liners, clean liner before each use. Scrub the liner surface with a stiff bristle scrub brush dipped repeatedly in one of the approved release agents.

Include jointing, form tie location and pattern of placement. Indicate backup, rustication, reveal, and chamfer strip locations.

Place rustication lines located as indicated within acceptable industry tolerances. Protect reinforcing steel from exposure to release agents. Form corners indicated to be chamfered with PVC chamfer.

Approved mock-up shall be the standard by which Work will be evaluated. Tensile Strength Ultimate D Menu Skip to content. Anchor liner to form on centers not to exceed 18 inches mm. Sectioning of column forms will eliminate this problem. Verify lines and levels of formwork and form liner patterns are within allowable tolerances.

  FLUXUS ADM 6725 PDF

Citation Styles for “Recommended practice for consolidation of concrete (ACI 309-72).”

Scott System Flex-Liner elastomeric form liner for creating textures in poured-in-place or precast concrete. Elongation D — percent: Thoroughly vibrate concrete to achieve consolidation, and minimize voids.

Storage of form liner shall be out of direct sunlight and in temperatures below degrees F 60 degrees C.

Wci vibrator contact with the form liner. Include concrete mix, forming system, form release agents, placement rate, form pressures, joint sealing, vibrating and stripping practices.

Light textures may get lost on a tall building. Use of some types of release agents will adversely affect the elastomeric urethane. ACI 78 — CH. Section — Tilt-Up Concrete. Maintain environmental conditions temperature, humidity, and ventilation within limits recommended by manufacturer for optimum results. Section — Concrete Formwork. Provide a mock-up for evaluation of surface preparation techniques and application workmanship.

Never try to match textures end to end, i. Contractor responsible for design of formwork and back-up of form liner for structural stability and sufficiency. When deciding on the extent of the 3099-72, consider all the major different types of work on the project. Section — Precast Concrete. Insert pattern number s of series required. Decrease centers as necessary to accommodate form stripping pressures without damaging liner intended for multiple use.

Full text of “ACI: Manual of Concrete Practice, Part 1”

Provide full scale mock-up using contract materials, methods and workmanship. Adi instructions and [ Product Data ] verifying compliance with specifications. Custom pattern as indicated on drawing. Store and use form liner panels at temperatures between 40 degrees F and degrees F.

  IEC 60584-1 PDF

Elastomeric form liners for texturing architectural concrete. Do not use 309-722 liner when continued use or repair would diminish the aesthetics of the Work.

There was a problem providing the content you requested

Internally vibrate into previous lift to avoid lift lines. Submit under provisions of Section Form liner layout and termination details. Proper cleaning and storage of form liner is required to obtain acceptable results. 3097-2, CO Tel: Hardness — D — Shore A: Cover form liners to protect from oil, dirt and UV exposure.

Try axi view the texture sample from a distance with sidelight for the best visual perspective of the texture. Section — Architectural Concrete. A minimum of 3 years experience with form liners similar to those required for this Project. Store and dispose of solvent-based materials, and materials used with solvent-based materials, in accordance with requirements of local authorities having jurisdiction.

After curing the forms are removed revealing the pattern created by the form afi.

Related Posts

  • JOAN MAGRETTA WHAT MANAGEMENT IS PDF
  • BS 2573-2 PDF
  • BIOCHEMICAL CALCULATIONS BY SEGEL PDF
  • CISCO CATALYST 6509 E DATASHEET PDF
  • AZB 8570 PDF
  • BACKTRACK WIFU PDF
  • ASTM A449 PDF
  • AS9101 REV D PDF
  • 6ED1 055-4MH00-0BA0 PDF
  • BHAVARTHA DIPIKA PDF
VPN
This website uses cookies to improve your experience. We'll assume you're ok with this, but you can opt-out if you wish. Cookie settingsACCEPT
Privacy & Cookies Policy

Privacy Overview

This website uses cookies to improve your experience while you navigate through the website. Out of these cookies, the cookies that are categorized as necessary are stored on your browser as they are as essential for the working of basic functionalities of the website. We also use third-party cookies that help us analyze and understand how you use this website. These cookies will be stored in your browser only with your consent. You also have the option to opt-out of these cookies. But opting out of some of these cookies may have an effect on your browsing experience.

Privacy Overview

This website uses cookies to improve your experience while you navigate through the website. Out of these cookies, the cookies that are categorized as necessary are stored on your browser as they are as essential for the working of basic functionalities of the website. We also use third-party cookies that help us analyze and understand how you use this website. These cookies will be stored in your browser only with your consent. You also have the option to opt-out of these cookies. But opting out of some of these cookies may have an effect on your browsing experience.

Necessary Always Enabled

Necessary cookies are absolutely essential for the website to function properly. This category only includes cookies that ensures basic functionalities and security features of the website. These cookies do not store any personal information.